One-Control-Six Synchronization Controller For Linear Actuator A / B / J (Model 0043039)

Regular price $782.00

Shipping calculated at checkout.

This synchronous controller is ideal for six linear actuators A / B / J. It controls six linear actuators simultaneously, ensuring they rise or fall synchronously. They work completely in sync without any difference.

Key Features:

  • It can operate six electric linear actuators A / B / J to run completely synchronously
  • Wired control via a touch control handle
  • Wireless control via a remote
  • If use an external antenna, the controller has a farther working range
  • The LED display on the control handle and remote control will display the stroke position in real time
  • Six touch function buttons: ▲, ▼, 1, 2, 3 and R
  • Buttons ▲ and ▼ are used to operate the linear actuators extension and retraction
  • Buttons 1, 2 and 3 are used to automatically operate the linear actuators to three pre-memorized positions
  • Button R is the reset button and is used to reset the system in case of an error
  • With a reset button and pairing button
  • When linear actuators move close to the end position, they will automatically slow down to protect themselves
  • When linear actuators are fully retracted, they will retain 1MM of travel to protect themselves
Introduction

If you want to use multiple linear actuators to raise and lower an equipment, for example two, four or more electric actuators. Since the high-speed DC motors in electric actuators cannot run at exactly the same speed, so the movement speed of the electric actuator will also be different. When multiple electric actuators work at the same time, their actual speeds cannot be exactly the same. In this case, we can use a synchronous controller to operate multiple linear actuators to rise or fall synchronously. They work completely in sync without any difference.

Working Principle

If you want to use a synchronization controller to operate two or more linear actuators fully synchronously, you will need to add built-in Hall effect sensors for each linear actuator. And when you purchase Hall effect sensors along with linear actuators, we will install Hall effect sensors in the linear actuators during production for you. When two or more linear actuators are running together, Hall sensor will send Hall signals to the synchronization controller, and the controller will adjust the running speed of each linear actuator, so that all linear actuators run at the exact same speed.

Specifications
Parameter Value
Operating Voltage 12~36 VDC, suitable for 12V or 24V linear actuator
Number of Connecting Linear Actuators 6
Maximum Output Current 10A / channel
Working Frequency 433.92 MHz
Two Selectable Control Modes Interlocking mode or Momentary mode, please select a control mode you need when ordering
Working Distance 30m / 90ft (theoretically)
Master Controller Case Size 155 x 150 x 52 mm (6.1 x 5.9 x 2.0 inches)
Slave Controller Case Size 124 x 104 x 34 mm (4.9 x 4.1 x 1.3 inches)
Operating Temperature -20°C ~ +70°C
Cable Length of the Touch Control Handle 2000±10%MM [80 in] (If you need a longer cable, please purchase the control handle extension cable)
Power Supply Selection

If you want to use this controller to synchronously control 6 linear actuators A/J, please use a 12V/50A or 24V/25A power supply.
If you want to use this controller to synchronously control 6 linear actuators B, please use a 12V/100A or 24V/50A power supply.

Connection

1) Use signal lines to connect the CAN-L and CAN-H terminals of the master controller to the CAN-L and CAN-H terminals of the slave controller.
2) Plug the touch control handle into the Hand Set port of the master controller. (Note: If the control handle is plugged into the Hand Set port of the slave controller, it will not function.)
3) Plug four linear actuators into the ports of channels CH1, CH2, CH3 and CH4 of the master controller, and then plug the remaining two linear actuators into the ports of channels CH1 and CH2 of the slave controller.
4) Connect the positive pole of DC power supply to the terminal <+> of the two controllers, and connect the negative pole of DC power supply to the terminal <-> of the two controllers.

Operation

1. Operation via the touch control handle:
Attention: The handle is operated by touch control. The touch sensitivity can be automatically calibrated when powered on for the first time. Hands are prohibited from touching the handle when powered on to prevent interference with the sensitivity calibration and affect the operating sensitivity.

1) Press and hold the ▲ button of the control handle, all linear actuators extend outward at the same time; Release the button, all linear actuators stop at the same time.
2) Press and hold the ▼ button of the control handle, all linear actuators retract inward at the same time; Release the button, all linear actuators stop at the same time.
3) Press any button 1, 2, or 3 on the control handle, all linear actuators will automatically move to the position memorized by that button and then automatically stop.
Note: You will need to first memorize three positions into these three buttons.
4) The LED display on the control handle will display the stroke position data in real time. For example, the number 03.5 means that the linear actuators have reached the stroke position of 35MM.

2. Operation via the remote control: (The remote control of the synchronous controller has two control modes, interlocking mode and momentary mode, please select a control mode you need when ordering)
2.1 When the controller is operating in momentary control mode:
1) Press and hold the button ▲ of the remote control, all linear actuators extend out at the same time; Release the button, all linear actuators stop at the same time.
2) Press and hold the button ▼ of the remote control, all linear actuators retract inward at the same time; Release the button, all linear actuators stop at the same time.

2.2 When the controller is operating in interlocking control mode:
1) Press the button ▲ of the remote control, all linear actuators extend out at the same time, they will reach the maximum stroke at the same time and stop automatically.
2) Press the button ▼ of the remote control, all linear actuators retract inward at the same time, they will fully retract at the same time and stop automatically.
3) During operation, you can also press any button of the remote control to stop all linear actuators at the same time.

How to Memorize three Stroke Positions

1) The controller can memorize total three stroke positions, and each button memorizes one stroke position.
2) First operate six linear actuators to the first suitable stroke position that you need to store, then press and hold the button 1 of the control handle for about 5-6 seconds, the stroke value on the LED display will flash twice. This means that the current stroke position is already stored in button 1.
3) You can continue to store the other two stroke positions into the button 2 and 3 by following the operation above.

Reset Function

When the LED display on the control handle shows the fault code, you need to reset the system as follows.
Reset operation: Press and hold the <R> button of the control handle or press and hold the <Reset> button on the master controller, or press and hold the ▲ and ▼ buttons on the remote control at the same time, until all linear actuators are reset to the bottom, and the LED display on the control handle shows "00.0", then release the button.

How to Pair the Remote Control to the Controller

Notice: We have paired the remote control to the controller before leaving the factory. If you want to pair more remote controls, please follow the following steps.
1) Press and hold the pairing button on the master controller for 8-9 seconds, until the green light flashes quickly, this indicates that the controller enters the learning status.
2) Press any one button on the remote control, this indicates that the pairing is successful.
3) The controller can learn several remote controls with different codes.

How to Delete all Remote Controls Codes Stored in the Controller

We have paired the remote control to the controller, if you don’t want the controller to work with the remote control, you can delete all remote controls codes stored in the controller.
Operation:
1) You need to open the master controller case, then you can see a small RF receiver module and there is a small learning button on the module.
2) Quickly and continuously press the learning button on the receiver module 8 times, then release the learning button, the signal LED on the receiver module flashes 8 times and then goes off, this indicates that all stored codes have been deleted successfully.

Import Customs Duty Explanation

1. Our store will offer one or two different shipping methods depending on the actual situation of the order. Since we ship from Hong Kong, China to worldwide, import duties will be incurred on the package regardless of which shipping method the customer chooses.

2. For small or lightweight packages, we will select a suitable freight company so that we can pay the import duties on the customer's behalf at the time of shipment. Therefore, the customer will not need to pay any import duties or taxes upon receiving the package.

3. For large or heavy packages, regardless of the freight company we choose, customs will collect import duties and taxes directly from the customer upon customs clearance or upon receipt of the package. The duty amount is usually 20% of the order amount (excluding shipping costs).

4. If the customer wishes us to pay the import duties on the customer's behalf, please contact us when placing the order and pay an additional 20% of the order amount as prepaid duties. We will then pay the duties for the customer.

5. If the customer chooses to pay the import duties themselves, please contact us after paying the duties and receiving the package. We will provide the customer with a discount voucher of a certain amount, which can be used for their next purchase. The discount amount will be the lesser of the import duties actually paid by the customer and 20% of the original order amount (excluding shipping costs).
Please note: We cannot refund cash for import duties paid by the customer themselves. Thank you for your understanding.

6. When the transport company or the customs informs the customer to pay the import duties, if the customer doesn't agree to pay, the package will be returned or destroyed, and the customer will need to bear all responsibility and cost.

Package Include

2 x Synchronous Controller (One four-channel master controller and one two-channel slave controller, One-Control-Six, For 6 Linear Actuators A / B / J with Hall effect sensors)
1 x Touch Control Handle
1 x Remote Control: CF-2
1 x User manual
Note: Six linear actuators A / B / J are not included, please order them separately. All linear actuators must be connected to the synchronous controller for the system to function properly. The remote control of the synchronous controller has two control modes, interlocking mode and momentary mode, please select a control mode you need when ordering.